♦ Product Description:
A residual current fire monitoring detector from the LDF5 series is a self-contained intelligent detector. The electric fire monitoring detector, as the relay part of the signal processing of the electrical fire monitoring system, can intelligently analyze and process the signal transmitted by the lower-level terminal probe through the built-in circuit and software, in order to judge the status of each probe of the lower-level terminal (that is, the fault state, fire alarm status, normal working status), and send the fault, alarm, and other information of each probe of the lower-level terminal to the electrical fire monitoring system. Monitoring and alarming processing in its entirety.
-
Residual current alarm value – 100-1000mA (settable)
- Temperature alarm value – 45-140°C
- Communication - RS 485 Inferface
- Communication distance ≤ 1000m
- Working temperature -30 °C~80°C
- Working environment humidity ≤90% RH
- Altitude ≤ 5000m
- Maximum power consumption – 5W
- Installation method- Pit mounted, standard 35 mm DIN rail
- Alarm output – passive normally open point (normal suction)
- Leakage circuit: 1, 4 , 8
- Temperature circuit: 1 , 5
♦ Basic Functions
Probe fault diagnosis, high alarm accuracy, strong reliability (can effectively prevent false alarms and omissions), miniaturization, multi-function, simple and practical, and easy installation are all features of the detector. It can be used for electrical safety and fire protection in hotels, business and summer gymnasiums, hospitals, libraries, computer rooms, bazaars, public cultural and entertainment venues, schools, cultural relics protection units, factory workshops, general warehouses, and other locations. It is not, however, suited for use in combustible, explosive, or severely corrosive conditions.
1. Most of new products are guaranteed for 12 months from the date of delivery, some for 18 months;
2. All products sent for repair shall be guaranteed for 6 months after repair;
3. Paid repair service can be provided for products beyond the warranty period.
There Are Three Ways to Contact ELEMRO to Place Orders
1. You can proactively contact ELEMRO through social media apps such as WhatsApp, Skype, Viber, and Facebook:
2. You can fill in your requirements in the bottom right corner of the webpage, and we will contact you as soon as we receive the requirements;
3. You can also contact various ELEMRO offices for offline communication and cooperation. Click here for ELEMRO office information.