neiye1

ZGLEDUN LDM9(CM1-Type) MCCB molded Case Circuit Breaker

Short Description:

ZGLEDUN Series LDM9(CM1-Type) molded case circuit breaker (hereinafter referred to as MCCB) is one of the new circuit breakers developed by our company with international advanced design and manufacturing technology. Its rated insulation voltage is 800V. It is suitable to be used for infrequent conversion and infrequent starting of the electromotor in circuits of AC 50Hz/60Hz, rated voltage of not higher than 690V (400V for series LDM9-63) and the rated working current up to 800A. The circuit breaker has functions of overload, short circuit and undervoltage protection, which can protect the circuit and power equipment from damage.
Products can be customized to suit your needs.


Product Detail

Product Tags

Product Standards:

This circuit breaker product implements the following standards:
◆ General rules of IEC60947-1 and GB/T14048.1
◆ IEC60947-2 and GB/T14048.2 Low voltage circuit breaker
◆ IEC60947-4 and GB/T14048.4 Contactors and motor starters
◆ IEC60947-5.1 and GB/T14048.5 Electromechanical control circuit appliances

Normal Working Conditions

◆Ambient medium temperature: not higher than +40℃ (+45℃ for common products) and not lower than -5℃. The average value of 24h does not exceed +35℃ (+40℃ for common products )
◆ Installation location: The altitude does not exceed 2000m;
◆ Installation location: The relative humidity of the air does not exceed 50% when the highest temperature is +40℃. It can have a higher relative humidity at a lower temperature. For example, relative humidity 90% at 20℃. Special measures should be taken for suspected exposure occasionally due to temperature changes.
◆ Installation category:
Main circuit of the circuit breaker and the undervoltage release: Grade III
Auxiliary circuits and control circuits: Grade II
◆ The circuit breaker can withstand the influence of humid air, salt mist, oil mist, mold and nuclear radiation.
◆ The maximum inclination of the circuit breaker installation is ±22.5°
◆ The circuit breaker can work reliably under earthquake conditions (4g);
◆ The circuit breaker should be installed in a place where there is no danger of explosion, no conductive dust, no corrosion of metal and no damage to insulation.
◆The circuit breaker should be installed in a place where there is no rain or snow.

Classification of Circuit Breaker

• Type A: The N pole is not equipped with an overcurrent release ( Shunt Trip ). The N pole is always on, and it is not switched on/off together with the other three poles.
• Type B: The N pole is not equipped with an overcurrent release ( Shunt Trip ) and is switched on/off together with other three poles (N pole is closed first and then opened).
• Type C: The N pole is installed with an overcurrent release ( Shunt Trip ) , and is switched on/off together with the other three poles (the N pole is off first and then on).
• Type D: N pole is installed with an overcurrent release ( Shunt Trip ) . The N pole is always on, and it is not switched on/off together with other three poles.

Rated current (A) :
• LDM9-63: (6A), 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A (6A without overload protection)
• LDM9-125: (10A), 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A, 125A
• LDM9-250: 100A, 125A, 140A, 160A, 180A, 200A, 225A, 250A
• LDM9-40 : 225A, 250A, 315A, 350A, 400A
• LDW9-630: 400A, 500A, 630A
• LDM9-800: 630A, 700A, 800A
[specification With ( ) is not recommended ]

Four Types of Wiring Method:
(1)Front-panel Wiring
(2)Back-panel Wiring
(3)Front-panel-inserted
(4)Back-panel-inserted

Two Types of Overcurrent Release (Shunt Trip):
(1)Thermal-electromagnetic (duplex) type
(2)Electromagnetic (instantaneous) type

Accessories of MCCB Molded Case Circuit Breaker : (1) with accessories and (2) without accessories.
There are internal accessories and external accessories.
Internal accessories include shunt trip, undervoltage release, auxiliary contact, and alarm .
External accessories include rotating handle operating mechanism, electric operating mechanism, interlocking structure, and wiring terminal blocks for auxiliary devices.

Series LDM9(CM1) MCCB Molded Case Circuit Breaker
Image Model No. Poles Unit Quantity/Carton
dasiggdgsdtre LDM9-63/3300 3P PC 16
LDM9-125/3300 3P PC 16
LDM9-250/3300 3P PC 12
LDM9-250/3300 3P PC 12
LDM9-400/3300 3P PC 4
LDM9-630/3300 3P PC 2
LDM9-800/3300 3P PC 2
LDM9-1250/3300 3P PC 1
gsdggweo LDM9-63/4300 4P PC 16
LDM9-125/4300 4P PC 16
LDM9-250/4300 4P PC 12
LDM9-400/4300 4P PC 4
LDM9-630/4300 4P PC 2
LDM9-800/4300 4P PC 2
LDM9-1250/4300 4P PC 1
Products can be customized to suit your needs.

  • Previous:
  • Next:

  • Write your message here and send it to us