Product Detail:
ZGLEDUN LDB9LE-63 series earth leakage circuit breaker (ELCB) or residual current circuit breaker (RCCB) are suitable for AC 50Hz/60Hz (or Customized), rated working voltage 1 pole 2 wires, 2 poles, 3 poles, 3 poles 4 wires, 4 poles 400V, rated current to 63A. ELCB is a safety device that quickly breaks an electrical circuit to protect equipment and to reduce the risk of serious harm from an ongoing electric shock. It can also prevent fire caused by the continuous ground fault due to the over-current protection device not operating. Earth Leakage circuit breakers with over-voltage protection can also protect against over-voltage caused by power grid faults.
This series of ELCB has been increasingly used as backup protection for ground faults and direct contact and indirect contact electric shocks in low-voltage power distribution systems.
Products can be customized to suit your needs.
The product complies with GB 16917-1 and IEC 61009-1 standards.
Working and installation conditions:
Ambient air temperature: the upper limit is not more than +40ºC, the lower limit is not less than -5ºC, and the average temperature of 24h does not exceed +35ºC.
Note: (1) If the lower limit is -10ºC or -25ºC working conditions, the user must declare to the manufacturer when ordering. (2) If the upper limit exceeds +40ºC or the lower limit falls below -25ºC, the user should consult with the manufacturer.
Installation location: no more than 2000m above sea level
Atmospheric conditions: The relative humidity of the atmosphere does not exceed 50% when the ambient air temperature is +40ºC. Higher relative humidity can be allowed at lower temperatures. For example, reaching 90% at +20ºC. Appropriate measures should be taken for occasional condensation due to temperature changes.
Installation conditions: The external magnetic field of the installation site should not exceed 5 times the geomagnetic field in any direction. Generally installed vertically, the handle upwards is the power-on position, with a tolerance of 2º in any direction. And there should be no significant impact or vibration at the installation site.
LDB9LE-63 High-breaking ELCB Earth Leakage Circuit Breaker (Series: DZ47S) | |||||
Image | Model No. | Related Current | Unit | Carton Pack (Small Shape) | Carton Pack (Big Shape) |
LDB9LE-63/1P | 1~4A | PC | 105 | 75 | |
LDB9LE-63/1P | 6~32A | PC | 105 | 75 | |
LDB9LE-63/1P | 40~63A | PC | 105 | 75 | |
LDB9LE-63/2P | 1~4A | PC | 75 | 60 | |
LDB9LE-63/2P | 6~32A | PC | 75 | 60 | |
LDB9LE-63/2P | 40~63A | PC | 75 | 60 | |
LDB9LE-63/3P | 1~4A | PC | 45 | 45 | |
LDB9LE-63/3P | 6~32A | PC | 45 | 45 | |
LDB9LE-63/3P | 40~63A | PC | 45 | 45 | |
LDB9LE-63/3P+N | 1~4A | PC | 45 | 30 | |
LDB9LE-63/3P+N | 6~32A | PC | 45 | 30 | |
LDB9LE-63/3P+N | 40~63A | PC | 45 | 30 | |
LDB9LE-63/4P | 1~4A | PC | 30 | 30 | |
LDB9LE-63/4P | 6~32A | PC | 30 | 30 | |
LDB9LE-63/4P | 40~63A | PC | 30 | 30 | |
Products can be customized to suit your needs. |
Normal Accessories for Miniature Circuit Breaker (Series: DZ47S) | |||||
Image | Item Number | Specification | Operating Voltage | Unit | Carton Pack (pcs/ctn) |
Overvoltage Release | MV | AC220V/110V or Custominzed | PC | 160 | |
Undervoltage Release | MN | AC220V/110V or Custominzed | PC | 160 | |
Overvoltage & Undervoltage Release | MV+MN | AC220V/110V or Custominzed | PC | 160 | |
Three-phase Four-Wire Overvoltage | MV+MN | AC220V/110V or Custominzed | PC | 160 | |
Shunt Trip+Auxiliary Contact | M×+OF with power supply | AC220V /110V DC24V or Custominzed | PC | 160 | |
Auxiliary Contact | OF | PC | 320 | ||
Shunt trip | SD | PC | 320 |
Product detail pictures:
Related Product Guide:
Trustworthy good quality and excellent credit score standing are our principles, which will help us at a top-ranking position. Adhering towards the tenet of "quality first, buyer supreme" for Wholesale Molded Case Circuit Breaker - Miniature ELCB Earth Leakage Circuit Breaker, Residual Current Operated Circuit Breaker ZGLEDUN LDM9LZ Series – Elemro , The product will supply to all over the world, such as: Guinea, Iceland, Saudi Arabia, Qualified R&D engineer will be there for your consultation service and we will try our best to meet your requirements. So please feel free to contact us for inquiries. You'll be able to send us emails or call us for small business. Also you are able to come to our business by yourself to get further knowing of us. And we will surely give you the best quotation and after-sale service. We're ready to build stable and friendly relations with our merchants. To achieve mutual success, we will make our best efforts to build a solid co-operation and transparent communication work with our companions. Above all, we are here to welcome your inquiries for any of our goods and service.
1. Most of new products are guaranteed for 12 months from the date of delivery, some for 18 months;
2. All products sent for repair shall be guaranteed for 6 months after repair;
3. Paid repair service can be provided for products beyond the warranty period.
There Are Three Ways to Contact ELEMRO to Place Orders
1. You can proactively contact ELEMRO through social media apps such as WhatsApp, Skype, Viber, and Facebook:
2. You can fill in your requirements in the bottom right corner of the webpage, and we will contact you as soon as we receive the requirements;
3. You can also contact various ELEMRO offices for offline communication and cooperation. Click here for ELEMRO office information.
By Joanne from panama - 2018.06.21 17:11
The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
By Ivy from South Africa - 2017.09.30 16:36