neiye1

SPD Surge Protective Devices T1 Level Graphite Core 10/350μs, Surge Protector ZGLEDUN Series LD-MD , Surge Arrester Lightning Protector

Short Description:

• Surge lightning protection

• Large discharge energy

• No leakage current

• No follow current

• Modular installation

• High Safety Level

• Long Service Life

• High environment adaptability

• The voltage protection level is less than 2500V

 

 


Product Detail

Product Tags

LD-MD series primary surge protective device (SPD) is designed according to IEC and GB standards. It is applied to the first-level surge protection of the power supply system. The SPD uses a standard 35mm rail type installation method.

The LD-MD series T1 level surge protector has a high lightning current discharge capacity. The maximum impulse current of a single module can reach 50KA (10/350μs), which can prevent various surges including direct lightning. It is applied to be the first-level surge protection device in power supply equipment systems in the areas of higher risk of lightning strikes. It can be combined for single-phase/three-phase power supply lines.

Application Sites:

◆General power distribution panel in the building

◆Overhead input distribution box in the building

◆Outdoor power distribution cabinet/distribution box

 

The Main Technical Parameters
Model LD-MD-A12.5 LD-MD-A15 LD-MD-A25 LD-MD-A50
SPD Port 1 Port 1 Port 1 Port 1 Port
SPD Type Voltage limiting type /Voltage switching type Voltage limiting type /Voltage switching type Voltage switching type Voltage switching type
Testing I I I I
Rated Voltage Un 110V/220V AC50-60Hz 110V/220V AC50-60Hz 110V/220V AC50-60Hz 110V/220V AC50-60Hz
Maximum Continuous Operating Voltage Uc (AC) 275V,320V,385V,420V,440V
Insulation resistance >100 MΩ >100 MΩ >100 MΩ >100 MΩ
Impulse Discharge Current limp (10/350 μs) 12.5KA 15KA 25KA 50KA
Protection Level Up (1.2/50 μs) 2.2 KV 2.2 KV 2.5 KV 2.8 KV
Response Time tA ≤100ns ≤100ns ≤100ns ≤100ns
Dimension (mm) 144x90x66 144x90x66 144x90x66 144x90x66
Installation Wire Cross-sectional Area mm² 6-25mm2
Installation 35mm Standard Rail (EN50022/DIN46277-3)
Working Environment Temperature ℃ -40ºC to 85ºC
Shell Material Plastic complied with UL94V-0
Protection Level IP20

 

 SPD Surge Protector 10-350 Type , T1 Level Graphite Core
  Image  Model Number Rated Current Quantity Per Carton Remark
  LD-MD-12.5KA(10-350) 4P 5~12.5KA 36 18mm  Samll Shell
LD-MD-15KA(10-350)   4P 5~15KA 18 36mm
LD-MD-25KA(10-350)   4P 10~25KA 18 36mm
LD-MD-50KA(10-350)   4P 25~50KA 18 36mm

T1 SPD INSTALLATIONN MEASUREMENTS

 


  • Previous:
  • Next: